Undermount Floor Vent Size Guide

Undermount floor vent sizes

Eight sizes: 2x12, 3x10, 4x10, 4x12, 4x14, 6x10, 6x12 and 6x14, the widest range we make.

Undermount sizing has two numbers that matter, and mixing them up is the one mistake that ruins an install. The duct opening is the hole in the floor, and it decides which size you order. The tray cut-out is what you cut in the subfloor so the tray can drop in and sit flush. They are different numbers. Cut to the tray cut-out.

Measure your DUCT OPENING. Match it to the range below.Your opening must fit within the range shown for the size you pick. Install the undermount base before laying your flooring. The flooring insert cut sizes below are for the piece that fits inside the tray, not the subfloor opening.

2 × 12

Duct openingmust fit within this range2–2½″ × 11¾–12¼″
Flooring insert cut sizecut the flooring piece that fits inside the tray1.02″ × 10.67″26 × 271 mm

3 × 10

Duct openingmust fit within this range2¾–3¼″ × 9¾–10¼″
Flooring insert cut sizecut the flooring piece that fits inside the tray1.77″ × 8.70″45 × 221 mm

4 × 10

Duct openingmust fit within this range3¾–4¼″ × 9¾–10¼″
Flooring insert cut sizecut the flooring piece that fits inside the tray2.76″ × 8.70″70 × 221 mm

4 × 12

Duct openingmust fit within this range3¾–4¼″ × 11¾–12¼″
Flooring insert cut sizecut the flooring piece that fits inside the tray2.76″ × 10.67″70 × 271 mm

4 × 14

Duct openingmust fit within this range3¾–4¼″ × 13¾–14¼″
Flooring insert cut sizecut the flooring piece that fits inside the tray2.76″ × 12.64″70 × 321 mm

6 × 10

Duct openingmust fit within this range5¾–6¼″ × 9¾–10¼″
Flooring insert cut sizecut the flooring piece that fits inside the tray4.72″ × 8.70″120 × 221 mm

6 × 12

Duct openingmust fit within this range5¾–6¼″ × 11¾–12¼″
Flooring insert cut sizecut the flooring piece that fits inside the tray4.72″ × 10.67″120 × 271 mm

6 × 14

Duct openingmust fit within this range5¾–6¼″ × 13¾–14¼″
Flooring insert cut sizecut the flooring piece that fits inside the tray4.72″ × 12.64″120 × 321 mm
Size Duct openingMust fit within this range Flooring insert cut sizeFlooring piece inside the tray
2 × 12 2–2½″ × 11¾–12¼″ 1.02″ × 10.67″26 × 271 mm
3 × 10 2¾–3¼″ × 9¾–10¼″ 1.77″ × 8.70″45 × 221 mm
4 × 10 3¾–4¼″ × 9¾–10¼″ 2.76″ × 8.70″70 × 221 mm
4 × 12 3¾–4¼″ × 11¾–12¼″ 2.76″ × 10.67″70 × 271 mm
4 × 14 3¾–4¼″ × 13¾–14¼″ 2.76″ × 12.64″70 × 321 mm
6 × 10 5¾–6¼″ × 9¾–10¼″ 4.72″ × 8.70″120 × 221 mm
6 × 12 5¾–6¼″ × 11¾–12¼″ 4.72″ × 10.67″120 × 271 mm
6 × 14 5¾–6¼″ × 13¾–14¼″ 4.72″ × 12.64″120 × 321 mm
◂ the DUCT OPENING ▸

How to measure

Replacing a vent?Pull the old one out and measure the bare duct opening. Match it to the duct opening range.

Installing undermount?Measure the actual vent base and duct opening before preparing the subfloor. Use the flooring insert cut size only for the flooring piece that sits inside the tray.

Works with flooring up to 20 mm (~13/16 in) thick.

Flooring insert cut size is the size of the flooring piece placed inside the vent tray. It is not the subfloor or duct opening size.

Free area and airflow by size

Free area is the open cross-section air actually passes through, not the outside of the cover, and not the nominal size on the label. It is the number that decides how much air a vent moves. We publish it for every size we sell.

Undermount Flush Floor Vent [Metal]: free area by size
Size Duct opening Duct opening (mm) Free area Open Airflow Price
2x122.17″ × 11.89″55 × 301.9 mm13.4 sq in50%≈ 46 CFMfrom $54.99 CAD
2x12 / 1
3x102.91″ × 9.92″73.9 × 251.9 mm12.2 sq in41%≈ 42 CFMfrom $54.99 CAD
3x10 / 1
4x103.89″ × 9.92″98.9 × 251.9 mm13.3 sq in33%≈ 46 CFMfrom $54.99 CAD
4x10 / 1
4x123.89″ × 11.89″98.9 × 301.9 mm15.3 sq in32%≈ 53 CFMfrom $59.99 CAD
4x12 / 1
4x143.89″ × 13.85″98.9 × 351.9 mm17.3 sq in31%≈ 60 CFMfrom $59.99 CAD
4x14 / 1
6x105.86″ × 9.92″148.9 × 251.9 mm15.4 sq in26%≈ 54 CFMfrom $59.99 CAD
6x10 / 1
6x125.86″ × 11.89″148.9 × 301.9 mm17.4 sq in24%≈ 61 CFMfrom $64.99 CAD
6x12 / 1
6x145.86″ × 13.85″148.9 × 351.9 mm19.4 sq in23%≈ 68 CFMfrom $69.99 CAD
6x14 / 1

Figures are calculated from factory drawings at 500 fpm face velocity with the damper fully open. See exactly how we calculate them, including what these numbers do and do not account for.

Frequently asked questions

Which number do I cut to?
The tray cut-out. The duct opening tells you which size to buy; the tray cut-out tells you what to cut.

What if my flooring is thicker than 20 mm?
The tray is designed for flooring up to 20 mm (~13/16"). Above that the grille will sit proud. Get in touch before ordering.

Can I fit an undermount without lifting the floor?
No, the tray goes under the flooring, so it needs the floor open. If the floor is staying down, use a drop-in floor vent instead.

Do undermount vents have a damper?
Yes, adjustable, so you can balance airflow room by room.